Tests of Coordinate Transfer from Magnetic to Mechanical Reference for LCLS Undulator Fiducialization
Levashov, Yu..
Fiducialization of the LCLS undulators will be based on magnetic measurements by Hall probe. Pointed magnets, proposed by I.Vasserman[1] for quadrupole lens .ducialization will be used as an intermediate reference. A prototype of the pointed magnet .xture has been made and tested. In this note we will describe a procedure for measuring the position of the center of the Hall probe sensitive area with respect to the undulator .ducial marks. The pointed magnet calibration procedure, a two-point alg... Show Full Abstract
Fiducialization of the LCLS undulators will be based on magnetic measurements by Hall probe. Pointed magnets, proposed by I.Vasserman[1] for quadrupole lens .ducialization will be used as an intermediate reference. A prototype of the pointed magnet .xture has been made and tested. In this note we will describe a procedure for measuring the position of the center of the Hall probe sensitive area with respect to the undulator .ducial marks. The pointed magnet calibration procedure, a two-point algorithm for locating the magnetic center of the .xture, and test results are presented. Show Partial Abstract